-
The new IATA DGR regulations on the state of charge of lithium battery goods in 2026
-
The BIS Bureau of India released the latest guidelines for the verification of the rated capacity of portable secondary lithium battery cells/batteries on November 11, 26.
-
Smartphone glass screen protectors will be included in the mandatory registration scope of India's BIS CRS starting from April 1, 27.
-
The latest battery regulation update of Taiwan's BSMI takes effect immediately
-
Good News: Shenzhen Chengce Testing has been awarded the recognition certificate by China Classification Society (CCS)
The BIS Bureau of India released the latest guidelines for the verification of the rated capacity of portable secondary lithium battery cells/batteries on November 11, 26.
Click:143Edit: 诚测认证
Time:2026-11-16 14:55:24
The BIS Bureau of India released the latest guidelines for the verification of the rated capacity of portable secondary lithium battery cells/batteries on November 11, 26.
Background
According to the Electronic and Information Technology Products (Compulsory Registration Requirements) Act 2021, 16046 (Part 2):2018 / IEC 62133-2:2017 is subject to compulsory registration regulation in India.
2. MeitY issued the Memorandum W-47/14/2024-IPHW on February 3, 2026, manmanally requiring: The rated capacity of portable sealed secondary lithium cells/batteries must be tested in accordance with clause 7.3.1 of 16047 (Part 3):2018/IEC 61960-3:2017 standard (Discharge performance at 20 ° C [rated capacity]). The test results are part of the declaration of the IS 16046 (Part2) compliance report.
Core testing requirements
Portable sealed secondary lithium battery cells and batteries need to undergo discharge performance (rated capacity) verification at 20℃, corresponding to the standard clause: IS 16047 (Part 3):2018/IEC 6600-3:2017 label Clause 7.3.1.
Implementation rules by subject:
A. The current certificate holder
1. Certificate validity: The obtained IS 16046 (Part2) certificate remains valid within its original validity period. However, the samples randomly inspected in the market must meet the requirements of the rated capacity limit.
2. Mandatory time node: May 1, 2027
From this date on, all certificate renewals, new model additions, and new registration applications must meet the rated capacity requirements. For certificates with an expiration date of 2027-05-01 or above, a third-party test report on the rated capacity must be submitted when renewing.
3. Requirements for Report Submission Operations
Provide a report issued by a third-party laboratory covering all the main models in the certificate, proving compliance with the capacity test terms.
Initiate the IS 16046 (Part2) test application through the LIMS system and submit the materials online in the "Standard Revision/Amendment/ Essential Requirement" module.
The test report needs to indicate the old report number corresponding to the past safety tests of this model. And fill in the measured capacity data in the unified reporting format Clause4 of the standard revision version.
4. Requirements for the Commitment letter: Submit a Undertaking commitment letter, stating that the remaining models listed in the certificate also meet the rated capacity standard terms.
5. Consequences: If the above actions are not completed on time, the certificate may be suspended, revoked, or the relevant model may be removed from the certificate scope.
B. New applicant
1. Rules for handling projects in transit
Applications that have already been sent to the laboratory or for which the laboratory has issued a test report do not require additional testing and can be processed in accordance with the capacity terms.
The IS 16046 (Part2) application under processing. The applicant undertakes to complete the rated capacity test report before the expiration of the license validity period, and the application process can proceed.
2. Mandatory time node: April 30, 2027
From this date, if the IS 16046 (Part2) test report lacks supplementary test results for rated capacity, no certificate will be issued.
C. Changes to the license scope/addition of models
When modifying the scope of the license or adding models, the rules for new applicants shall be followed. The mandatory requirement for rated capacity will come into effect from May 1, 2027.
Version validity
This guideline supersedes the old implementation guideline 16046 (Part 2) issued on February 10, 2026, and comes into effect on the date of its release.
Compliance advice
For the main models that have been issued certificates but still need to be shipped to India, it is recommended that all capacity supplementary tests and registrations be completed before May 1, 2027. Before the mandatory time node, it is essential to reserve sufficient time for testing, certification and registration, and plan the schedule as early as possible to avoid the shipping risks caused by the congestion of testing and registration.
2. For new applications from Chinese factories, as the current certification cycle IS relatively long, it is recommended to immediately conduct the rated capacity test of the main model simultaneously with 16046 (Part2). Starting from April 30, 2027, no certification will be issued for IS 16046 (Part2) test reports without capacity test data.
3. For certificate renewal, if the certificate expires on or after May 1, 2027, a rated capacity test report must be submitted. It is essential to complete the capacity tests and registrations of all main models before the certificate expires to avoid affecting the renewal.


Related News
-
The latest battery regulation update of Taiwan's BSMI takes effect immediately
The Bureau of Standards, Metrology and Inspection of the Ministry of Economic Affairs of Taiwan Region issued this announcement on November 17, 2026, which shall come into effect as of the date of the announcement. The main content is to include (or redefine) nine types of secondary lithium battery-related products in the scope of compulsory inspection. Safety tests and restricted substance labeling shall be carried out in accordance with the new CNS standards, and the conformity assessment model and implementation schedule shall be adjusted simultaneously.
13
2026-11-24
-
The BIS Bureau of India released the latest guidelines for the verification of the rated capacity of portable secondary lithium battery cells/batteries on November 11, 26.
Background: 1. According to the Electronic and Information Technology Products (Compulsory Registration Requirements) Act 2021, 16046 (Part 2):2018 / IEC 62133-2:2017 is subject to compulsory registration regulation in India. 2. MeitY issued the Memorandum W-47/14/2024-IPHW on February 3, 2026, manmanally requiring: The rated capacity of portable sealed secondary lithium cells/batteries must be tested in accordance with clause 7.3.1 of 16047 (Part 3):2018/IEC 61960-3:2017 standard (Discharge performance at 20 ° C [rated capacity]). The test results are part of the declaration of the IS 16046 (Part2) compliance report.
143
2026-11-16
-
Smartphone glass screen protectors will be included in the mandatory registration scope of India's BIS CRS starting from April 1, 27.
The Electronics and Information Authority of India made the following amendments to the Electronic and Information Technology Products (Mandatory Registration Requirements) Order 2021 on September 21, 2026
356
2026-11-12

English
中文



